Call out job at customers home today.

This ski didn't water come out from side of water outlet when flushing at the jetty.

Problem was this flushing hose.

Flushing hose was kinked and choke water flow from tap water.


Worst case this may cause over heat problem when flushing (normally over heat warning start) however if ski on a water doesn't over heat this case because cooling water pick up from jet pump unit and through X-pipe (see above pic) then go to motor.
X-pipe has 4 of connection, 1 from Jet pump pick up cooling water as IN (OUT when flushing ), 1 for motor as OUT, 1 for Inter cooler as OUT and 1 for flushing as Stop (IN when flushing) In short when ski run on a water cooling water doesn't go to flushing side because if hose kinked doesn't matter but when flushing if this hose kinked water doesn't go to engine and get over heat.
 Do you understand what I'm saying?